SIMPLEX Addressable Smoke Detector with Base 4098-9714 + 4098-9789

Simplex 4098-9714 True Alarm Photoelectric Sensor / Detector  0742444CN

The Simplex 4098-9714 True Alarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing.  Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration.  Sensitivity is selected and monitored at the fire alarm control panel.

The sensor head design provides 360° smoke entry for optimum response to smoke from any direction.  A built-in screen keeps insects from entering the smoke chamber.  Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow.

Inquiry Form

We will get in touch with you shortly

Description

Description

Features

  • True Alarm analog sensing provides:
    • Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications
  • For use with the following Simplex® products:
    • 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details)
    • 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation
  • Fire alarm control panel provides:
    • Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection
    • Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity
    • Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot
    • Ability to display and print detailed sensor information in plain English language
  • Photoelectric smoke sensors provide:
    • Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3)
  • Heat sensors provide:
    • Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F
    • Rate-of-rise temperature sensing
    • Utility temperature sensing
    • Listed to UL 521 and ULC-S530
  • General features:
    • Operation is for ceiling or wall mounting
    • Listed to UL 268 and ULC-S529
    • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted
    • Designed for EMI compatibility
    • Magnetic test feature is provided
    • Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator
  • Additional base reference:
    • For isolator bases, refer to data sheet S4098-0025
    • For sounder bases, refer to data sheet S4098-0028
    • For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address)