SIEMENS SITRANS FX330 Vortex Flowmeter

Siemens SITRANS FX Vortex flowmeter are designed for use in industrial applications and optimally suited to the demands in auxiliary supply systems. The proven principle of vortex flowmeters is suitable for measure ment of liquids, gases and vapors unaffected by conductivity, viscos ity, temperature and pressure.

Even the basic version of the vortex flowmeter SITRANS FX330 is equipped with temperature compensation for saturated steam applications. With the optional pressure sensor the SITRANS FX330 has integrated density compensation for calculation of corrected volume and mass (online density compensation). The density com pensation for calculation of corrected volume and mass is based on the standards of NIST for gases and IAPWS for steam.

Higher measuring accuracy with the use of compact measuring systems.

With the classic installation of a vortex flowmeter and separate pres sure and temperature sensor as well as flow calculator, all errors occurring in the measuring chain must be taken into account when determining system accuracy. This can result in a measuring error between ± 3 to 5 %.

Using a vortex flowmeter with integrated pressure and temperature compensation such as the SITRANS FX330 allows you not only to lower installation costs but also increase the measuring accuracy of the measuring point. In this case the accuracy is ± 1.5 % of the measured value.

Inquiry Form

We will get in touch with you shortly

Description

Description

Benefits 

  • Integrated pressure and temperature compensation
  • Temperature compensation for saturated steam included as stand ard
  • High measuring accuracy
  • Maintenance-free sensor Non-wearing, fully welded stainless steel construction with high resistance to corrosion, pressure and temperature
  • SIL2 certified according to IEC 61508 Edition 2
  • Use in hazardous areas
  • Integrated reduction of nominal diameter for space-saving and economic installation and large measuring ranges
  • Redundant data management: Easy exchange of electronics without loss of calibration and configuration data
  • FAD (Free Air Delivery) functionality
  • Gross and net heat calculation to support advanced energy man agement
  • Remote version with cable length up to 50 m (164 ft)

Specification

Nominal size flanged version DN15  to DN300 (½”  to 12”)
Nominal size sandwich version DN15  to DN100 (½”  to 4”)
Process values Volume flow, mass flow, corrected volume flow, density, temperature, pressure,  heat energy
Accuracy Steam and gases: +/- 1%

Liquids: +/- 0.75%

Current output 4 – 20 mA HART (loop powered)
Digital output Pulse (max. 1000 Hz), frequency, status, limit switch
Communication HART 7, Profibus PA and Foundation Fieldbus in preparation
Pressure rating PN 10 – 100; Class 150 – 600
Medium temperature -40 … 240 °C (-40 … 464 °F)
Material sensor Stainless steel 1.4404 (316L), Hastelloy C22 on request
Transmitter enclosure Die-cast aluminium
Enclosure rating IP66 / 67 (NEMA 6)
Connection EN 1092-1; ASME B16.5

Wafer design (centering rings included)

Remote transmitter Connection cable up to 50m (164 ft), remote version in preparation
Temperature sensor Standard integrated temperature sensor
Pressure sensor Optional integrated pressure sensor with or without isolation valve
Display and keypad High-resolution graphical display and 4 operating keys (alternative use magnet pen)
Ex approvals ATEX II2 G Ex ia – QPS IS Class I Div.1 – IECEx II2 G Ex ia

ATEX II2 G Ex d – QPS XP Class I Div.1 – IECEx II2 G Ex d

ATEX II3 G Ex nA – QPS NI Class I Div. 2 – IECEx II3 G Ex nA

ATEX II2 D Ex tb – QPS DIP Class II, III Div. 1 – IECEx II2 D Ex tb

Safety integration level (SIL) SIL2 according to IEC 61508
Application examples chemical, power, and oil and gas installations