Yokogawa US300FM Ultrasonic Flowmeter
Production Description
The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing and correlation detection method, US300FM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids.
Comes with transducers in three sizes that accommodate pipe sizes from 25mm to 6500mm
Inquiry Form
We will get in touch with you shortly
Categories: Flow Measurement Technologies, Instrumentation
Brand: YOKOGAWA
Description
Description
US300FM Performance
| Fluid | Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s) |
| Measured values | Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid (when optional wall thickness probe is provided) |
| Pipe size | 25 to 6,500 mm |
| Pipe material | Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc. |
| Flow velocity range | 0.01 to 25 m/s |
| Fluid temperature range | -30 deg to +130 deg C. (general use) -30 deg to +200 deg C. (high-temperature use) |
| Accuracy | 1% to 3% of reading (depends on application) |
| Straight pipe run upstream | More than 10 D (depends on the piping conditions) |
Main unit construction
| Housing material | Aluminum (powder coated) |
| Water/dust proof | IP65 |
| Dimensions (HxWxD) | 200 mm x 280 mm x 71 mm |
| Weight | Approx. 2.8 kg |
Transducer construction
| Case material | Stainless steel SUS316 Ti |
| Water/dust proof | IP65 (General purpose), IP67 (Immersible) |
Functions
| Calculation of the two flow inputs | Two values from an average (for two path measurement), sum, or difference for channel A and channel B inputs |
| Time-programmable measurement | Automatic start and stop of measurement using internal clock. Can be used with data logging or communication function. |
| Parameter setting storage | Storage of pipe and fluid parameters (Maximum of 80 different settings) |
| Sound velocity measurement | Measurement of the sound velocity in the liquid |
Features
- More accurate measurements under difficult conditions
- New noise suppression technique improves accuracy of measurements with fluids where air bubbles are present
- Fast response
- Yokogawa signal processing technology improves the speed and accuracy of measurements
- Easy installation and adjustment of transducers
- Transducers are small and light – can be held in one hand
- Each sensor calibrated before shipment, eliminating need to tune on-site
- No longer necessary to adjust the zero flow condition
- Easy setup with interactive parameter setting process
- Two flow-input channels are provided as an option
- A maximum of two current outputs enable the simultaneous measurement of flow and sound velocity