KROHNE/OPTIFLUX 1100 Electromagnetic Flowmeter

Electromagnetic flowmeter for general applications with conductive liquids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

Inquiry Form

We will get in touch with you shortly

Description

Description

General information

Product type Flowmeter
Product family name OPTIFLUX
Product positioning For general applications with conductive liquids
Measurement principle Electromagnetic
Measured media Liquids

Operating conditions

Process pressure max. 16 barg/
230 psig
Process temperature -25…+120°C/
-13…+248°F

Materials

Liner Perfluoroalkoxy alkane (PFA)

Process connections

Flange connections EN (1092-1): DN10…150
ASME (B 16.5): ⅜…6″
JIS (B 2220): 10…150A
Other connections Sandwich (wafer) connection:
DN10…150
⅜…6″
10…150A

Approvals/Standards

Certificates/Approvals Marine ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS

Communication

Analogue outputs 4…20 mA
Discrete outputs Pulse, Frequency, Status
Digital outputs HART®