KROHNE OPTISWIRL 2100 Vortex Flow Meter

Vortex flowmeter for basic utility applications

  • For liquids, (wet) gases, saturated and superheated steam (+240°C / +464°F)
  • Available with integrated nominal diameter reduction for a large measurement span also in pipelines with large diameters
  • Flange: DN15…300 / ½…12″; wafer version: max. DN100 / 4″
  • 2-wire, 4…20 mA, HART®7

Inquiry Form

We will get in touch with you shortly

Description

Description

Product features and options depend on device configuration:

  • Economic flowmeter design
  • Flange or space-saving sandwich (wafer) version (up to DN100 / 4″)
  • Advanced technology for signal filtering (AVFD Advanced Vortex Frequency Detection)
  • Optional F1R/F2R version enables cost-saving installation without expensive pipeline reduction
  • Available as compact (C) or remote field (F) version
  • Robust construction (I66/67)
  • High-resolution graphical display turnable in 90° steps
  • Alternative operation using bar magnet while housing is closed
  • HART®7 communication protocol
  • Ex ia, Ex d approvals

General information

Product type Flowmeter
Product family name OPTISWIRL
Product positioning For basic utility applications
Measurement principle Vortex
Measured media Liquids, Gases, Steam

Operating conditions

Process pressure max. 100 barg/
1450 psig
Process temperature -40…+240°C/
-40…+464°F

Materials

Measuring tube Die-cast stainless steel (1.4408/CF8M)
Process connection Austenitic stainless steel (1.4404/316L), Die-cast stainless steel (1.4408/CF8M), Carbon steel (A105)

Process connections

Flange connections EN (1092-1): DN15…300
ASME (B 16.5): ½…12″
JIS (B 2220): 15…300A
Other connections Sandwich (wafer) connection:
EN (1092-1): DN15…100
ASME (B 16.5): ½…4″

Approvals/Standards

Certificates/Approvals Others NACE
Certificates/Approvals Ex ATEX, cQPSus, IECEx

Communication

Analogue outputs 4…20 mA
Discrete outputs Pulse
Digital outputs HART®