KROHNE OPTISWITCH 6700 Capacitive Level Transmitter

Capacitance level switch for hygienic and industrial applications

  • With IO-Link interface for quick configuration; two freely programmable outputs available, e.g. IO-Link/PNP, IO-Link/NPN, IO-Link/4…20 mA, etc.
  • Point level detection of liquids, solids and liquid-liquid interface
  • -40…+115°C / -40…+239°F (extended length version up to +150°C / +302°F); non-hygienic version up to 100 bar / 1450 psi

Inquiry Form

We will get in touch with you shortly

Description

Description

Specifications

Depending on selected device configuration

General information

Product type Level switch
Product family name OPTISWITCH
Product positioning For hygienic and industrial applications
Product variants OPTISWITCH 6700 C: Compact housing
Measurement variables Level
Measurement principle Capacitance
Level measurement type Point level detection
Contact to measured medium Yes
Interface measurement Yes
Redundancy No
Measured media Liquids, Liquid/liquid interface, Foam, Slurries, Pastes, Solids, Bulk solids, Granulates, Powders

Operating conditions

Process pressure -1…100 bar/
-14.5…1450 psi
Variant with G½ hygienic: max. 10 bar / 145 psi
Variant with sliding connection: max. 5 bar / 72,5 psi
Process temperature -40…+115°C/
-40…+239°F
Variant with sliding connection: up to +150°C / +302°F

Materials

Gaskets Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM), Nitrile butadiene rubber (NBR), Silicone
Wetted parts Polyetheretherketone (PEEK)

Process connections

Thread connections Male:
G½ (ISO 228-1)
G½ (DIN 3852-E)
½ NPT
G¾, reverse-threaded (ISO 228-1)
G½ for hygienic adapters
Hygienic adapters Collar ferrule (DIN 11851): DN25, DN40, DN50
Tri-Clamp®: 1½”, 2″
Clamp (DIN 32676): DN25, DN32, DN40, DN50
Clamp (ISO 2852): 25, 38, 51
Varivent®: N
Collar ferrule (SMS 1147): 51 mm
Weld-in sleeve: 30 mm / 1.2″
Weld-in sleeve with shoulder: 29 mm / 1.1″
Collared weld-in sleeve: 45 mm / 1.8″
Spherical weld-in sleeve: 35 mm / 1.2

Approvals/Standards

Certificates/Approvals Hygienic FDA, EHEDG, EC 1935/2004, EC2023/2006
Ingress protection IP67, IP69K

Communication

Analogue outputs 4…20 mA
Discrete outputs NPN/PNP
Digital outputs IO-Link

 

Features & Options:

    • Level switch with IO-Link communication for automated sensor configuration
    • Problem solver for adhesions and difficult products: level detection not affected by product build-up, foam or condensate
    • Two switching outputs for different trigger thresholds allow monitoring of different processes or measured media
    • Switch points can be indicated by 360° multicolour LEDs: available with transparent polycarbonate collar or with the LEDs collar-protected by a metal crown
    • Stainless steel housing with PEEK sensor material
    • Optimal sensor shape: Easy-to-clean, minimised risk of clogging by sticky products
    • Maintenance-free, can be installed in any mounting position
    • Wide variety of hygienic adapters available
    • Also available with a sliding connection for tanks with thick wall thickness / insulation or to overcome high process temperature
    • Sensor version with reverse-threaded G¾ connection allows for mounting in a pipe extension tube for low level detection from the top

 

Other Available Models:
  • OPTISWITCH 6500
  • OPTISWITCH 6600
  • OPTISWITCH 6700