Siemens SITRANS FX Vortex flowmeter are designed for use in industrial applications and optimally suited to the demands in auxiliary supply systems. The proven principle of vortex flowmeters is suitable for measure ment of liquids, gases and vapors unaffected by conductivity, viscos ity, temperature and pressure.
Even the basic version of the vortex flowmeter SITRANS FX330 is equipped with temperature compensation for saturated steam applications. With the optional pressure sensor the SITRANS FX330 has integrated density compensation for calculation of corrected volume and mass (online density compensation). The density com pensation for calculation of corrected volume and mass is based on the standards of NIST for gases and IAPWS for steam.
Higher measuring accuracy with the use of compact measuring systems.
With the classic installation of a vortex flowmeter and separate pres sure and temperature sensor as well as flow calculator, all errors occurring in the measuring chain must be taken into account when determining system accuracy. This can result in a measuring error between ± 3 to 5 %.
Using a vortex flowmeter with integrated pressure and temperature compensation such as the SITRANS FX330 allows you not only to lower installation costs but also increase the measuring accuracy of the measuring point. In this case the accuracy is ± 1.5 % of the measured value.
Inquiry Form
We will get in touch with you shortly
Description
Benefits
- Integrated pressure and temperature compensation
- Temperature compensation for saturated steam included as stand ard
- High measuring accuracy
- Maintenance-free sensor Non-wearing, fully welded stainless steel construction with high resistance to corrosion, pressure and temperature
- SIL2 certified according to IEC 61508 Edition 2
- Use in hazardous areas
- Integrated reduction of nominal diameter for space-saving and economic installation and large measuring ranges
- Redundant data management: Easy exchange of electronics without loss of calibration and configuration data
- FAD (Free Air Delivery) functionality
- Gross and net heat calculation to support advanced energy man agement
- Remote version with cable length up to 50 m (164 ft)
Specification
Nominal size flanged version | DN15 to DN300 (½” to 12”) |
---|---|
Nominal size sandwich version | DN15 to DN100 (½” to 4”) |
Process values | Volume flow, mass flow, corrected volume flow, density, temperature, pressure, heat energy |
Accuracy | Steam and gases: +/- 1%
Liquids: +/- 0.75% |
Current output | 4 – 20 mA HART (loop powered) |
Digital output | Pulse (max. 1000 Hz), frequency, status, limit switch |
Communication | HART 7, Profibus PA and Foundation Fieldbus in preparation |
Pressure rating | PN 10 – 100; Class 150 – 600 |
Medium temperature | -40 … 240 °C (-40 … 464 °F) |
Material sensor | Stainless steel 1.4404 (316L), Hastelloy C22 on request |
Transmitter enclosure | Die-cast aluminium |
Enclosure rating | IP66 / 67 (NEMA 6) |
Connection | EN 1092-1; ASME B16.5
Wafer design (centering rings included) |
Remote transmitter | Connection cable up to 50m (164 ft), remote version in preparation |
Temperature sensor | Standard integrated temperature sensor |
Pressure sensor | Optional integrated pressure sensor with or without isolation valve |
Display and keypad | High-resolution graphical display and 4 operating keys (alternative use magnet pen) |
Ex approvals | ATEX II2 G Ex ia – QPS IS Class I Div.1 – IECEx II2 G Ex ia
ATEX II2 G Ex d – QPS XP Class I Div.1 – IECEx II2 G Ex d ATEX II3 G Ex nA – QPS NI Class I Div. 2 – IECEx II3 G Ex nA ATEX II2 D Ex tb – QPS DIP Class II, III Div. 1 – IECEx II2 D Ex tb |
Safety integration level (SIL) | SIL2 according to IEC 61508 |
Application examples | chemical, power, and oil and gas installations |